五月天 在线 一区_国产精品高清系列在线观看_99视 欧美婷婷色_亚洲国产成人精品电影_日日摸天天摸人人看

Full Spectrum Micropate Reader

RNE-90001 Full Spectrum Micropate ReaderIntroduction1)RNE90001 is a microprocessor –controlled, general purpose photometer system designed to read and calculate the result of assays, including co

  • Brand: REAGEN
  • Model: RNE90001
  • Launch: 2014
  • Specs: platform

RNE-90001 Full Spectrum Micropate Reader

image34.jpg

Introduction

1)RNE90001 is a microprocessor –controlled, general purpose photometer system designed to read and calculate the result of assays, including contagion, tumorous mark, hemopathy, dyshormonism, which are read in microtiter plate.

2)Touch panel let your operation easily.


3)Multiple calculations:


lAbsorbance mode (ABS)


lCut-Off mode


lSingle standard mode


lPoint to point mode


l% Absorbance Multi-Point Mode


lLinear regression mode


lExponent regression mode


lLogarithm regression mode


lPower regression mode


4) isualization mark plate,you can set blank, 


control, sample ,standard in any place,and


run mostly 12 different tests in one 96 micr


plate.


5) Test time <5s/plate,and mix plate before


test

6)Item parameter settings: parameters of 120 detection items can be set, saved and queried for future detection;

7)Detection calibration: detection calibration is enabled, calibration parameters of 120 last items can be saved, calibration parameters can be transferred while do the same item

detection;  

                                         

Parameters of instrument

Weight:

8.1kg

Overall dimensions:

430mmL×335mmW×175mmH

Power:

a.c.110V~220V50-60Hz

Fuses:

T2AL250V

Work Environment:

temperature 10-30℃;Humidity ≤70%

Store Environment:

-20-55℃;Humidity ≤93%

Standard Wavelength:

405,450,492,630nm,Ten optical fibers can be configured within 400 to 800 at a

time;

Instrument sensitivity:

no less than 0.01L/mg.

Instrument channel difference:

less than 0.01A.

Range of operating wavelength:

400-800nm;

Detection range:

0.000-4.000A;

Resolution ratio:

0.001A;

Plate reading velocity:

5s of single waveform, 10s of dual wavelength;

Warm up time:

10 minute

Interface:

RS-232C serial interface, USB interface

Display:

5.7″LCD display320×240 discernibility,256 gray scale

Input:

Touch panel and pen,

Accuracy

±0.01(0.000-2.000nm)

Linear error

±1.0%(0.000-2.000nm)

Accurate wavelength

±3.0nm



企業(yè)愿景

    公司將一如既往的視誠信為最重要的文化精神;在經(jīng)營決策和管理的全過程中信守“以產(chǎn)品質(zhì)量、優(yōu)質(zhì)服務(wù)”為原則和“為人類健康服務(wù)”為宗旨的理念;融前沿科技、全球資源與優(yōu)質(zhì)人才為資本,以開拓創(chuàng)新、銳意進取、精益求精之精神,科學管理之導向,凝聚員工、客商之合力,同舟共濟,為實現(xiàn)人類的食品安全和生物醫(yī)藥業(yè)的高速發(fā)展不懈奮斗!

查看更多